Maxx Ice MIM250 Návod k použití a péči Strana 18

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 23
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 17
16
machine splash areas, plus the interior surfaces of the bin, deflector and door with the remaining
sanitizing solution. Inspect to insure that all functional parts, fasteners, thermostat bulbs (if used),
etc. are in the correct position.
12. Press the Clean button for 6 seconds and the water will be purged and the green and yellow
LEDs will be blinking together. Allow to drain until sanitizer has been flushed down the drain
and continue to purge to the diluted sanitizing solution for another 1 to 2 minutes. Then press the
controller to OFF
13. Turn the machine ON and replace the front panel.
14. Discard the first two ice harvests. DO NOT USE any ice produced from the cleaning solution.
Control Panel (located at left side of front bottom louver panel)
Zobrazit stránku 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23

Komentáře k této Příručce

Žádné komentáře